There are exceptions however, one being applied where the equipment has leakage current that would impair on its reliable operation. exposure to elements, vibration, production line) and the connection to the supply. is the electrical equipment Class 1, exposed conductive parts), external influences (e.g. When determining what an increased risk of electric shock is, we take into consideration the electrical equipment or appliance being used (e.g. The purpose of the clause is to essentially minimise the risk of electric shock. Directly connected stationary equipment within a high risk area.Īll other final sub-circuits not in excess of 32 Amp are to be assessed RCD compatible and if so should be RCD protected to ensure they are both safe and compliant.Power circuits for socket outlets (1, 2 & 3 Phase).The RCD requirements for final sub-circuits has increased to 32 Amp, from the previous 20 Amp to provide personal protection from electric shock to the following circuits: 30mA RCDs shall be installed on all final sub-circuits supplying 32 Amp fixed wired equipment that may classify as an increased risk of electric shock e.g.30mA RCDs should be installed on all final sub-circuits supplying 32 Amp fixed wired equipment.30mA RCDs shall be installed on all final sub-circuits supplying socket outlets and lighting below 32 Amps.The new AS/NZS 3000 wiring rules require additional RCD protection: In commercial and industrial environments, all 32 Amp outlets and below need to be protected by an RCD. One of the major changes to the AS/NZS 3000: 2018 is the Residual Current Devices (RCD) requirements for the protection of sub-circuits and relating alterations and repairs (clause 2.6.3.2.3).Įveryone in the industry is bound by them and every customer is the beneficiary.

The changes have taken into account new technologies, new products and improvements in safety, whist clarifying on the previous versions ambiguous requirements. Register your interest and we will get in touch to come and visit and train you and your staff.New clause preventing electric shock in Commercial BuildingsĮffective January 1 st, 2019 was the new edition of the AS/NZS 3000 Wiring Rules Standard (Electrical Installations), which outlined over 200 changes and expanded upon the coverage of electrical installations.
#As nzs 3000 wiring rules download
You can download our 8 page brochure below to discover some of the ways the new AS/NZS 3000 Wiring Rules will grow your business by up to 30%.Īlso, our reps will be conducting toolbox training sessions in your area, where you will receive a copy of our guide to the changes. For specific circumstances, refer to the AS/NZS 3000:2018 Wiring Rules.

Please be aware that this is only a guide to some of the changes in regulations and does not cover every individual situation. This guide outlines the changes to the regulations that relate to our products and offers recommendations for best application. To simplify things, we have created a guide to help you navigate some of these changes. They include more than 200 important changes you need to be aware of which are linked to the development of new technologies, new products and an improvement in safety. The AS/NZS 3000:2018 Wiring Rules have been released in June 2018.